Issue 53
D. Wang et alii, Frattura ed Integrità Strutturale, 53 (2020) 236-251; DOI: 10.3221/IGF-ESIS.53.20 236 Monitoring and analysis of reinforced concrete plate-column structures under room temperature and fire based on acoustic emission Dongye Wang Huaqiao University, Xiamen 361021, China Xiamen City University, Xiamen 361008, China WangDY2269@outlook.com Yuli Dong * , Dashan Zhang, Weihua Wang, Xin Lu Huaqiao University, Xiamen 361021, China dongyl@hqu.edu.cn, zhangds@hqu.edu.cn, whwang@hqu.edu.cn, 469316910@qq.com A BSTRACT . This paper attempts to disclose the damage mechanism of reinforced concrete plate-column structures under room temperature and fire. Several tests were carried out to record the law of crack development on the plate surface under room temperature. The infrared detection technology was adopted to observe how cracks develop under fire. The acoustic emission (AE) signals at different positions of the specimen were monitored by the AE techniques. Coupled with the macroscopic test phenomena, several characteristic parameters collected by the AE system, namely, cumulative number of events, event rate, energy rate and b-value, were analyzed in details. The results show that: the cumulative number of events was active in the loading, heating and cooling stages; the crack density and the change of internal forces could be derived from the trend of event rate; the local energy changes of the specimen could be deciphered from the curves of energy rate and b-value, making it possible to judge if a component has reached the failure state; the specimen suffered the most severe damage, when the AE parameters suddenly changed; AE monitoring enables the early warning of fire to reinforced concrete plate-column structure; infrared detection technology is suitable for real-time monitoring of crack development under high temperature. K EYWORDS . Plate-column structure; Acoustic emission (AE); Fire test; Cumulative number of events; Event rate; Energy rate; Gutenberg-Richter parameter (b-value). Citation: Wang, D.Y., Dong, Y.L., Zhang, D.S., Wang, W.H., Lu, X., Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission, Frattura ed Integrità Strutturale, 53 (2020) 236-251. Received: 25.02.2020 Accepted: 10.05.2020 Published: 01.07.2020 Copyright: © 2020 This is an open access article under the terms of the CC-BY 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Made with FlippingBook
RkJQdWJsaXNoZXIy MjM0NDE=