Issue 51

C. Ferrero et alii, Frattura ed Integrità Strutturale, 51 (2020) 92-114; DOI: 10.3221/IGF-ESIS.51.08 102 applied to improve material properties due to the presence of injections and good mortar. In particular, the coefficient related to injections (equal to 1.5 [20]) was used for stone masonry panels retrofitted during past interventions, while the coefficient related to good quality mortar (equal to 1.5 [20]) was adopted for brick masonry. The values of the tensile strength were estimated from the shear strength proposed by the Italian Circolare [20] using the relations and recommendations provided in [21, 22]. The values of fracture energies were determined based on information available in literature [22, 23]. Material property Stone masonry Stone masonry (+ injections) Brick masonry (+ good mortar) Specific weight [kN/m 3 ] 21 21 18 Elasticity modulus [MPa] 1740 2610 2250 Poisson's ratio [-] 0.2 0.2 0.2 Compressive strength [MPa] 2.67 4.00 4.00 Compressive fracture energy [N/mm] 4.27 6.40 6.40 Tensile strength [MPa] 0.108 0.163 0.190 Tensile fracture energy [N/mm] 0.024 0.024 0.024 Table 2: Material properties of the different types of masonry considered in the numerical model. The physical and mechanical properties adopted for reinforced concrete (beams) and steel (tie-rods) are reported in Table 3. Since no mechanical characterization was available for these materials, such properties were derived from NTC2008 [17]. Material property Concrete Steel Specific weight [kN/m 3 ] 25 78.5 Modulus of elasticity [MPa] 31500 210000 Poisson's ratio [-] 0.2 0.29 Table 3: Material properties of reinforced concrete and steel. Regarding the diaphragms, their bending and axial stiffness were computed by DIANA software [19] considering the elasticity modulus of the material assigned to the slabs and the thickness of the FEs adopted to model them. In this work, an equivalent modulus of elasticity ( E ) and an equivalent thickness ( h ) were calculated based on the real bending and axial stiffness of a strip of slab as wide as the spacing between the principal elements composing slab structure. An isotropic and orthotropic material was employed for two-way and one-way slabs, respectively. For two-way slabs, the same stiffness was adopted in all directions. Contrarily, for one-way slabs the stiffness in the secondary direction was assumed as the 10% of the one adopted in the principal direction, based on a sensitivity analysis on the global modal response. The stiffness in the orthogonal vertical direction was estimated in accordance with the requirements of orthotropic elasticity reported in [19]. Table 4 presents the in-plane axial stiffness in the principal and secondary directions ( E 1 h and E 2 h ) and the bending stiffness in the vertical direction ( E 3 h 3 /12) for the different types of slab present in the building. Type of diaphragm Type of material E 1 h (kN/m) E 2 h (kN/m) E 3 h 3 /12 (kNm) Lightweight concrete slab (one-way) orthotropic 3.00E+06 3.00E+05 7.05E+03 Lightweight concrete slab (two-way) isotropic 2.64E+06 2.64E+06 1.06E+04 Steel slab (one-way) orthotropic 3.82E+05 3.82E+04 6.62E+02 Roof isotropic 1.89E+06 1.89E+06 5.67E+02 Table 4: Properties adopted for the diaphragms in the numerical model.

RkJQdWJsaXNoZXIy MjM0NDE=