Issue 49
E.U.L. Palechor et alii, Frattura ed Integrità Strutturale, 49 (2019) 614-629; DOI: 10.3221/IGF-ESIS.49.56 621 Figure 14 : LabView control panel. The flowchart of the methodology validation The following flowcharts presents a scheme for the validation of the proposed damage identification method – see Fig. 15: Figure 15 : Flow chart of the methodology proposed. Simulation of Damage Discretization of Beam n elements n+1 nodes Damage identification Method propose Impact Force Positioning Additional Mass at node Get time signal Application of Exponential Window Application of Fast Fourier Transform (FFT) Identification of the Maximum Values of the FFT Application of Frequency Correction Method Last Position of Mass Plotting of discrete values: Frequencies vs. mass position Interpolation values (Cubic Spline) Application of Discrete Wavelet Transform (DWT) Localization of Damage Add Gaussian Noise