Issue 39
J. Navrátil et alii, Frattura ed Integrità Strutturale, 39 (2017) 72-87; DOI: 10.3221/IGF-ESIS.39.09 75 Figure 3 : Stress-strain diagram of reinforcing steel used for the analysis. Figure 4 : Normal force–horizontal displacement diagrams according to [2] vs. IDEA StatiCa. Ref. [2] experiment Ref. [2] calculation IDEA results Difference experiment Difference calculation F max [kN] 454 447 436 δF max = – 3.96 % δF max = – 2.46 % w Fmax [mm] 26.1 25.1 24.4 δw Fmax = – 6.51 % δw Fmax = – 2.79 % Table 1 : Comparison of results. The values of ultimate resistance F max and corresponding horizontal displacement w Fmax obtained by the IDEA StatiCa solver are compared with the data stated in reference [2], see Tab. 1. Some improvements might be obtained by refining the model and increasing number of load steps and the requirements for the precision of iteration. The results of non-linear analysis were tested against the moment-normal force interaction diagram, both calculated in IDEA StatiCa. Moment-normal force response of critical section of the column was calculated using both force and displacement control of non-linear analysis. Displacement control analysis is in excellent agreement with the ultimate limit state of critical cross-section, see Fig. 5.